Heating Automation for Apartments and Houses
A compact apartment with two or three rooms may benefit from two or three independently controlled temperature zones, if the manifold and heating circuits support that separation. Use separate schedules where occupancy genuinely differs.


Small apartments
A compact apartment with two or three rooms may benefit from two or three independently controlled temperature zones, if the manifold and heating circuits support that separation. Use separate schedules where occupancy genuinely differs.
In a very open-plan space, additional zones may offer little extra value if rooms have nearly identical thermal behaviour.

Larger single-storey houses
Four to six zones often cover typical living, sleeping and work spaces, but the correct count depends on how rooms are used rather than floor area alone. A living room with two pipe loops can still be one zone.
Plan thermostat positions and keep a labelled manifold-zone map for future service.
More about the system →
Two-storey homes
If floors have separate manifolds, plan controller placement, power and communication accordingly. Multiple controllers may be appropriate for larger or distributed installations.
Avoid assuming that the number of loops equals the number of zones or that one controller belongs automatically to one floor.

Choose wired or wireless around the building
Wireless Q20 control is attractive in completed interiors where routing thermostat cables is difficult. Wired Q10 control suits new builds and extensive renovations with prepared wiring. Both can provide room-by-room temperature regulation.
The installation environment, serviceability and component compatibility should decide the architecture.
More about the system →
Mixed radiators and underfloor heating
Radiators react more quickly than underfloor heating, so set schedules accordingly. QTV20 smart radiator valves can regulate individual radiators while a separate Q20 arrangement manages floor-heating circuits.
Boiler-demand coordination and hydraulic design must be checked, especially if both types of emitters share one heat source.

Choosing a zoning layout for an apartment or multi-storey home
In a compact apartment, two or three intelligently chosen zones may be sufficient: for example, living area, bedroom area and a separate work room. In a larger house the number of independently managed areas may increase, especially when floors have different solar exposure, occupancy or heat losses. Zone count follows real comfort needs, not marketing kit sizes.
Start with the manifold: count loops, identify what each loop actually serves and decide whether adjacent loops share a temperature schedule. A multi-storey property can require additional controller capacity or a separate controller arrangement according to the installation design; it should not be assumed that one control unit can reach every circuit.
For finished properties, wireless Q20 room communication can avoid major cable work, provided the radio signal can be tested reliably. In a new build or full renovation, wired Q10 connections may be particularly convenient because cables can be planned with the rest of the electrical works.
Use simple commissioning records: room, thermostat model, zone number, actuator outputs, heat source connection and final setpoints. This prevents the classic situation where the displayed name is correct but the physically controlled circuit belongs to another room.

Practical installation and commissioning
An effective heating automation project should be checked in the actual building, not judged only by the interface. Record the room, thermostat, heating loop, actuator output and desired schedule. After installation, request heat independently in each zone and verify the correct circuit. Use the official wiring and pairing instructions for electrical and radio equipment; a qualified installer should perform electrical work.
For evaluating comfort changes, observe comparable days and adjust one setting at a time. Underfloor heating responds slowly, and a displayed setpoint does not represent measured consumption. An honest energy comparison requires real meter readings and reasonably similar weather and occupancy.
Choose zones by use, not simply by floor area
For a smaller apartment, prioritise spaces with genuinely different heating needs, such as a living room and bedrooms. In a larger house, consider floor level, south-facing rooms, home offices and separately used guest areas. One thermostat per zone is a planning tool; one thermostat per every hydraulic loop is not necessarily needed.
Where there are two manifolds or two floors, plan the required number of controllers and document which circuits each one operates. Verify the heat-source interface and the total actuator load. The best design balances individual comfort against equipment count and remains straightforward for the household to operate.
How to verify the result
After making a change, record the previous setting and the reason for it. Check the result across several comparable days rather than judging a slow underfloor system after a few minutes. If comfort deteriorates or rooms begin to overshoot, restore the previous programme and investigate zone balancing, sensor position and boiler operation.
Components and system examples
Q20 Wireless Thermostat for Underfloor Heating AutomationRead guide →
Q30 e-Ink Wireless Thermostat for Underfloor Heating AutomationRead guide →
Q50 Touchscreen Thermostat for Wired Underfloor Heating AutomationRead guide →
Q40 Wired Smart Thermostat for Underfloor Heating AutomationRead guide →
Q10 Wired Thermostat for Underfloor Heating AutomationRead guide →
Installation manuals
Open PDF manual ↗
Open PDF manual ↗Technical guides already published
Frequently asked questions
Small apartments
A compact apartment with two or three rooms may benefit from two or three independently controlled temperature zones, if the manifold and heating circuits support that separation. Use separate schedules where occupancy genuinely differs.
Larger single-storey houses
Four to six zones often cover typical living, sleeping and work spaces, but the correct count depends on how rooms are used rather than floor area alone. A living room with two pipe loops can still be one zone.
Two-storey homes
If floors have separate manifolds, plan controller placement, power and communication accordingly. Multiple controllers may be appropriate for larger or distributed installations.
Choose wired or wireless around the building
Wireless Q20 control is attractive in completed interiors where routing thermostat cables is difficult. Wired Q10 control suits new builds and extensive renovations with prepared wiring. Both can provide room-by-room temperature regulation.