Q10 Wired Underfloor Heating Controller: Complete Guide

Q10 Wired Underfloor Heating Controller
UNDERFLOOR HEATING · WIRED CONTROLLER

Q10 Wired Underfloor Heating Controller Complete Guide

How the Q10 wiring controller coordinates room thermostats, thermal actuators, the circulation pump and heat-source demand in a wired zoned heating system.

Up to 8 zones Q10 / Q40 / Q50 Wired room control Pump + heat source
Sponsored guide. Product examples are based on Quicksmart heating controls. The article explains underfloor-heating zoning, controller architecture and manifold control.
WHAT THE CONTROLLER DOES

One wiring centre coordinates the complete zoned system.

The Q10 controller is installed near the underfloor-heating manifold and receives the heating requests from the wired room thermostats.

When a room calls for heat, Q10 energises the actuator or actuators assigned to that zone. The controller can also coordinate the circulation pump and the demand signal to the heat source.

8 Zones

Up to eight room zones can be controlled independently.

230 V Actuators

Designed to control manifold actuators in the heating system.

PUMP Output

Coordinates the circulation pump according to heating demand.

ON/OFF Heat source

Provides demand control for the boiler or other compatible source.

SYSTEM FLOW

A fixed wired path from thermostat to manifold

The control cable carries the room demand to the Q10 controller, which then operates the manifold and system outputs.

01

Wired thermostat

Q10, Q40 or Q50 monitors its room and sends the demand by cable.

02

Q10 controller

Centralises the room requests and activates the required zone output.

03

Thermal actuator

Opens the loop or loops assigned to the requesting room.

04

Pump + heat source

The controller coordinates the system only when there is an active heating demand.

Best planned before the walls are finished.
WIRED ARCHITECTURE

Best planned before the walls are finished.

A wired controller architecture is particularly suitable for new builds and full renovations where the thermostat cable routes can be planned together with the electrical installation.

The result is a fixed, organised system with the room controls permanently connected to the manifold controller.

Suitable for new construction and full renovation
Fixed thermostat-to-controller wiring
Q10, Q40 and Q50 wired thermostat options
Controller also coordinates pump and heat-source demand
Q10 ECOSYSTEM

Room controls for the wired architecture

The Q10 controller can be paired with different wired thermostat styles while the manifold actuators perform the same physical job of opening the heating loops.

Q40 Wired thermostat
WIRED

Q40 Wired thermostat

In-wall thermostat with LCD display and touch controls.

Read guide ↗
Q50 Wired thermostat
PREMIUM

Q50 Wired thermostat

4-inch TFT colour touchscreen for a premium room interface.

Read guide ↗
Q10 controller
CONTROLLER

Q10 controller

Central wiring controller installed near the manifold.

NC actuator
MANIFOLD

NC actuator

Opens or closes the corresponding floor-heating loop.

SYSTEM SIZING

The room count and the loop count solve different parts of the design.

Thermostats are selected by the number of independently controlled rooms or areas. Actuators are selected by the number of floor-heating loops that need to be opened and closed at the manifold.

Thermostats for underfloor heating automation

SYSTEM EXAMPLE

Explore compatible Quicksmart heating controls

See Q20 Wireless, Q10 wired controllers, room thermostats, manifold actuators and complete underfloor-heating control configurations.

Visit Quicksmart
FAQ

Common questions

How many zones can the Q10 controller manage?
The Q10 controller is designed for up to eight independently controlled zones.
Which thermostats are used with Q10?
The wired Quicksmart architecture can use Q10, Q40 and Q50 room thermostats depending on the project and desired interface.
Does Q10 control the circulation pump?
The Q10 architecture includes pump control as part of the central system coordination.
Is Q10 better suited to new construction?
It is especially practical when thermostat control cables can be planned before finishes are completed.
Do six rooms always mean six actuators?
No. Six controlled rooms normally mean six thermostats, but the actuator count depends on how many manifold loops serve those rooms.