Underfloor Heating Controllers: Q20 Wireless vs Q10 Wired

Q20 underfloor heating controller Q10 underfloor heating controller
UNDERFLOOR HEATING · CONTROLLER GUIDE

Underfloor Heating Controllers Q20 Wireless vs Q10 Wired

A practical guide to choosing the control architecture for zoned underfloor heating: wireless thermostats with Q20, wired thermostats with Q10, actuators on the manifold and the right number of zones for the property.

Up to 8 zones Wireless or wired Thermostats + actuators New build or retrofit
Sponsored guide. Product examples and system architecture are based on Quicksmart heating controls. The editorial explanation is written for practical comparison and system planning.
START HERE

A heating zone is not the same thing as a heating loop.

A zone is the room or area controlled by one thermostat. A loop is a pipe circuit connected to the manifold. One zone can contain one loop or several loops.

That is why a 4-zone system normally uses four thermostats, but it may need more than four actuators. The actuator count follows the number of manifold loops assigned to the controlled zones.

Zone Room or area controlled independently
Thermostat Usually one per controlled zone
Loop Pipe circuit on the manifold
Actuator Usually one per controlled loop
TWO ARCHITECTURES

The same zoning logic. Two different ways to connect the room controls.

Both systems can control rooms independently. The main difference is how the thermostats communicate with the controller and how easily the system can be integrated into an existing building.

Q20 wireless controller at underfloor heating manifold
Q20 WIRELESS

Wireless from the room to the manifold

Q20 or Q30 thermostats communicate wirelessly with the Q20 controller. This avoids control cabling between the rooms and the manifold and is especially useful in finished homes and retrofit projects.

Q20 / Q30 wireless thermostats
Q20 controller at the manifold
e-Hub for Smart Life control
Optional RF receiver for boiler demand
Q10 wired controller at underfloor heating manifold
Q10 WIRED

Fixed wiring from each thermostat to the controller

The room thermostats are wired to the Q10 controller. This architecture is particularly suitable for new builds and full renovations where the thermostat cables can be planned before the finishes are completed.

Q10 / Q40 / Q50 wired thermostats
Q10 controller at the manifold
Direct control of thermal actuators
Pump and heat-source demand control
Q20 VS Q10

Controller comparison at a glance

Feature Q20 Wireless Q10 Wired
Thermostat communication Wireless Wired
Maximum zones per controller Up to 8 Up to 8
Typical thermostat family Q20 / Q30 Q10 / Q40 / Q50
Manifold actuators Controlled by controller Controlled by controller
Smart control Via e-Hub / Smart Life Depends on thermostat / system configuration
Typical project Finished homes, retrofit, flexible installation New build, full renovation, planned wiring
Q20 WIRELESS ARCHITECTURE

How the Q20 system works

Each room thermostat sends its heating demand wirelessly to the Q20 controller. The controller then opens the actuator or actuators assigned to that zone.

01

Room thermostat

Q20 or Q30 measures room temperature and sends the heating demand wirelessly.

02

Q20 controller

Receives the zone demand and controls the corresponding manifold outputs.

03

Actuators

Open only the loops assigned to zones that currently need heat.

04

Heat source

The system can send boiler demand directly or through the RF receiver, depending on configuration.

Q10 WIRED ARCHITECTURE

How the Q10 system works

Each wired thermostat sends its demand to the Q10 controller. The controller coordinates the zone actuators and can also manage the circulation pump and heat-source demand.

01

Wired thermostat

Q10, Q40 or Q50 monitors the room and sends the heating demand through the control cable.

02

Q10 controller

Centralises the room requests and energises the required manifold outputs.

03

Actuators

Open the loops assigned to the rooms that are requesting heat.

04

Pump + heat source

The controller can coordinate the circulation pump and the heat-source demand.

ROOM CONTROLS

The thermostat count follows the number of zones.

If you want three rooms to operate independently, you normally need three thermostats. The choice of thermostat family depends on whether the architecture is wireless or wired.

Q20 Wireless
WIRELESS

Q20 Wireless

Touch wireless thermostat for the Q20 system.

Read guide ↗
Q30 Wireless
WIRELESS

Q30 Wireless

Premium wireless option with e-Ink display, Li-Ion battery and USB-C charging.

Read guide ↗
Q40 Wired
WIRED

Q40 Wired

Wired in-wall thermostat with LCD display and touch controls.

Read guide ↗
Q50 Wired
WIRED

Q50 Wired

Premium wired thermostat with 4-inch TFT colour touchscreen.

Read guide ↗
Q10
WIRED

Q10

Surface-mounted wired room thermostat for Q10 zone control.

Read guide ↗

Thermostats for underfloor heating automation

NC 230V actuator for underfloor heating manifold
MANIFOLD CONTROL

The actuator count follows the loops — not just the rooms.

Thermal actuators are installed on the manifold valves. When a zone requests heat, the controller powers the actuator or actuators assigned to the loops serving that zone.

A large living room may be one zone with one thermostat but three or four floor-heating loops. In that case, that single thermostat can control several actuators through the controller.

NCNormally Closed
230 VSupply
M30 × 1.5Thread
IP54Protection
UNDERFLOOR HEATING CONTROL SYSTEM

Controller, wiring centre, thermostats and actuators work as one system.

In a zoned underfloor heating control system, the room thermostat creates the heating demand, the controller or wiring centre decides which outputs should be active, and the thermal actuators open the required manifold loops. The system should therefore be sized by both the number of independently controlled zones and the number of heating loops on the manifold.

THERMOSTATS

How many thermostats do I need?

As a practical rule, use one thermostat for each independently controlled zone. A 2-zone layout normally uses two thermostats; a 3-zone layout normally uses three; a 4-zone layout normally uses four; and a 6-zone layout normally uses six.

Thermostat count follows zones
ACTUATORS

How many actuators do I need?

Count the floor-heating loops that must be controlled. One room can be a single zone while using several loops, which means one thermostat can command several actuators through the controller.

Actuator count follows controlled loops
SYSTEM SIZING

How many zones do you need?

Zone count should follow how the rooms are used, not simply the total floor area. The goal is to group spaces that can realistically share the same temperature and schedule.

2–3 zones

Apartments and smaller homes

A compact system often separates day and night areas, or gives the main rooms independent control.

Typically 2–3 thermostats · actuator count by loops
4–6 zones

Larger homes and multi-room projects

Useful when living areas, bedrooms, offices, bathrooms or different floors need their own temperature schedules.

Typically 4–6 thermostats · one or more manifold groups
CHOOSING THE ARCHITECTURE

Wireless or wired? Start with the building, not the thermostat.

Choose wireless when

the home is already finished
you want to avoid new control cables
thermostat placement may need flexibility

Choose wired when

the project is a new build
the home is undergoing a full renovation
the control wiring can be planned before finishing
SYSTEM EXAMPLE

See compatible Quicksmart control systems

Explore Q20 Wireless and Q10 wired components, thermostats and underfloor-heating automation examples.

Visit Quicksmart
FAQ

Common questions about underfloor-heating controllers

Do I need one thermostat for every underfloor-heating loop?
No. A thermostat normally represents a controlled zone. One zone can contain several floor-heating loops, so one thermostat can control several actuators through the controller.
Is the number of zones the same as the number of actuators?
Not necessarily. Zone count follows independently controlled rooms or areas. Actuator count follows the manifold loops that must be opened and closed.
When is a wireless controller system useful?
Wireless room controls are particularly useful in finished homes and retrofit projects where new thermostat cables would be difficult or undesirable.
When is a wired controller system useful?
Wired systems are especially practical in new builds and full renovations where the thermostat control cables can be planned before the wall finishes are completed.
Can one controller manage several rooms independently?
Yes. Both Q20 and Q10 are designed for zoned control, with each thermostat associated with its own controlled zone.

Leave a Comment