Wireless Underfloor Heating Automation – Complete Guide
With Q20 Wireless, Q20 or Q30 room thermostats send 868 MHz RF signals to the Q20 manifold controller. The controller operates NC thermal actuators for the zones requesting heat. A separate RF receiver can provide compatible boiler demand, while the e-Hub gives access to Smart Life / Tuya remote functions.

Wireless Underfloor Heating Automation – Complete Guide

How wireless zone automation works
With Q20 Wireless, Q20 or Q30 room thermostats send 868 MHz RF signals to the Q20 manifold controller. The controller operates NC thermal actuators for the zones requesting heat. A separate RF receiver can provide compatible boiler demand, while the e-Hub gives access to Smart Life / Tuya remote functions.
Local radio control and internet app connectivity are different paths. Losing internet access can remove remote access without necessarily stopping local temperature regulation. Placement and signal range should be checked in the actual building.

Q20 and Q30: choosing room interfaces
Q20 uses an illuminated negative LCD display, touch controls and AA batteries or a supported USB supply. Q30 has an e-Ink display, rechargeable Li-Ion battery and USB-C charging. Both can be assigned to independent zones within a compatible Q20 automation installation.
Select the display and power arrangement that suits the occupants, then place the thermostat where it measures representative room temperature. Do not place it close to a radiator, direct sun, exterior draught or an appliance that runs hot.
More about the system →
Designing the manifold layout
One room may contain two or more heating loops, so actuator quantity can exceed thermostat quantity. The Q20 controller provides up to eight zones per controller; separate manifolds or larger installations can require additional controllers. Label each actuator connection and zone during commissioning.
The optional receiver and e-Hub serve distinct functions: heat-source switching versus connected app management. Confirm what is present in each kit before assuming boiler control or remote access is included.

Use scheduling to avoid unnecessary heating
A home office used only on working days can have a different schedule from a bedroom. For underfloor heating, temperature changes should account for slab thermal inertia and usually work better as modest setbacks than sudden deep reductions.
After a few days, compare actual room comfort with the programmed targets and refine the schedule. This is operational optimisation, not a direct measurement of energy consumption.
More about the system →
Retrofit checks and commissioning
Before installation, check RF coverage, e-Hub connectivity where needed, the manifold valve threads, actuator power supply and the heat-source ON/OFF input. A qualified installer should verify mains wiring and boiler connections.
Test the heat request from each thermostat and confirm that only its assigned circuits open. Record the zone map and keep the system manual available for later maintenance.

How to plan and commission a Q20 wireless zone system
Q20 and Q30 room thermostats communicate by radio with the Q20 underfloor heating controller. The controller operates the assigned thermal actuators at the manifold and coordinates heating demand according to the installed configuration. The e-Hub is used for the Smart Life interface, while the separate RF receiver is relevant to appropriate heat-source control arrangements. Their responsibilities should not be confused.
A renovation may benefit from radio room thermostats because new low-voltage or mains control cables need not be routed between every finished room and the manifold. The controller, actuators and other powered components still require their specified electrical connections. Radio performance should be tested at the actual installation positions, particularly through dense masonry and across floors.
Document the zone assignment before pairing: living area, bedroom, office and bathrooms should be matched to the real manifold loops. A room with two loops can require two actuators but still one thermostat. Pair and test one zone at a time, observe whether its actuator opens, and label the wiring-centre outputs clearly.
For energy-conscious operation, use different comfort schedules where occupancy justifies it and avoid dramatic overnight setbacks in high-inertia floors. Remote monitoring of room temperature and setpoints does not automatically constitute electrical or gas energy metering in kilowatt-hours.

Practical installation and commissioning
An effective heating automation project should be checked in the actual building, not judged only by the interface. Record the room, thermostat, heating loop, actuator output and desired schedule. After installation, request heat independently in each zone and verify the correct circuit. Use the official wiring and pairing instructions for electrical and radio equipment; a qualified installer should perform electrical work.
For evaluating comfort changes, observe comparable days and adjust one setting at a time. Underfloor heating responds slowly, and a displayed setpoint does not represent measured consumption. An honest energy comparison requires real meter readings and reasonably similar weather and occupancy.
Commissioning wireless zones reliably
Start with the location of the manifold and the walls separating it from the rooms. Test radio communication at the intended thermostat positions before final fixing. A Q20 controller receives heat requests from Q20 or Q30 room thermostats and operates the appropriate thermal actuators. The e-Hub adds remote app access; it is not a replacement for the local control path.
Assign clear room names in the app and check each zone one at a time. Increase the target temperature temporarily to confirm the associated actuator receives a command, then restore the normal setpoint. Check the RF boiler receiver independently where one is included. Avoid presenting the system as having no wires at all: the thermostats communicate wirelessly, but the controller and actuators still require their specified electrical connections.
How to verify the result
After making a change, record the previous setting and the reason for it. Check the result across several comparable days rather than judging a slow underfloor system after a few minutes. If comfort deteriorates or rooms begin to overshoot, restore the previous programme and investigate zone balancing, sensor position and boiler operation.
Components and system examples
Short product demonstrations
Smart control is not a direct measurement of kWh consumption.
Installation manuals
Open PDF manual ↗
Open PDF manual ↗Technical guides already published
Frequently asked questions
How wireless zone automation works
With Q20 Wireless, Q20 or Q30 room thermostats send 868 MHz RF signals to the Q20 manifold controller. The controller operates NC thermal actuators for the zones requesting heat. A separate RF receiver can provide compatible boiler demand, while the e-Hub gives access to Smart Life / Tuya remote functions.
Q20 and Q30: choosing room interfaces
Q20 uses an illuminated negative LCD display, touch controls and AA batteries or a supported USB supply. Q30 has an e-Ink display, rechargeable Li-Ion battery and USB-C charging. Both can be assigned to independent zones within a compatible Q20 automation installation.
Designing the manifold layout
One room may contain two or more heating loops, so actuator quantity can exceed thermostat quantity. The Q20 controller provides up to eight zones per controller; separate manifolds or larger installations can require additional controllers. Label each actuator connection and zone during commissioning.
Use scheduling to avoid unnecessary heating
A home office used only on working days can have a different schedule from a bedroom. For underfloor heating, temperature changes should account for slab thermal inertia and usually work better as modest setbacks than sudden deep reductions.